Skip to content

Regulatory Compliance

We prepare suppliers for CMMC 2.0 certification and US Department of Defense contracts

CMMC is a condition of US Department of Defense contracts that include the requirement. Phase 2 of the rollout began on 10 November 2026: in applicable solicitations a Level 2 certification by a C3PAO is now a condition of award. We guide suppliers - including those outside the US - through information scoping, assessment against NIST SP 800-171 Rev. 2 and certification readiness, based on a real project delivered for a US DoD contractor in Europe.

Last updated: October 2026

30 minutes with a consultant who runs projects like yours. We agree the scope and tell you what the price depends on.

Industries
5
Years in the market
8+

Team certifications

  • CISSP - Certified Information Systems Security Professional
  • CISA - Certified Information Systems Auditor
  • CISM - Certified Information Security Manager
  • OSCP - Offensive Security Certified Professional
  • OSWE - Offensive Security Web Expert
  • GICSP - Global Industrial Cyber Security Professional
  • GRID - GIAC Response and Industrial Defense
  • IEC 62443 - ISA/IEC 62443 Cybersecurity Expert
  • BSCP - Burp Suite Certified Practitioner

Regulatory Compliance

  • CMMC level determination
  • CUI enclave scoping
  • System Security Plan (SSP)

The Cybersecurity Maturity Model Certification (CMMC 2.0) is a US Department of Defense programme that conditions participation in defense contracts on demonstrating compliance with information protection requirements. It applies across the supply chain - including European firms that are subcontractors to US contractors, supply equipment, services or construction for US military installations, or want to enter that market. The growing US military presence in Europe means this is no longer exotic. The difficulty is that the requirements are spread across the final CMMC rule, NIST SP 800-171 Rev. 2 (110 requirements in 14 families; CMMC has not adopted Rev. 3), the SPRS system and contract clauses - and incorrect scoping can multiply the cost of compliance or, conversely, leave a gap that voids certification. We brought a general contractor on a US military construction project in Europe into compliance - in parallel under CMMC 2.0 and the Risk Management Framework for the building automation systems. We offer that same pragmatism - the right scope first, then a realistic plan - to suppliers entering the defense supply chain.

Scope of the service

  • CMMC level determination - whether the entity processes FCI (Level 1) or CUI (Level 2), and which assessment mode applies (self-assessment or C3PAO certification)

  • CUI enclave scoping - defining the boundary of systems processing covered information, so as not to certify the whole organisation where a separated enclave suffices

  • System Security Plan (SSP) - developing and maintaining documentation of scope, architecture and implemented safeguards

  • Gap analysis against NIST SP 800-171 Rev. 2 - assessment of 110 requirements across 14 control families, with a numeric score

  • SPRS score - calculating and preparing the entry in the Supplier Performance Risk System per DoD methodology

  • Remediation plan (POA&M) - prioritised actions with a timeline, closing gaps against the required level

  • C3PAO assessment preparation - evidence completeness, readiness testing and support during the assessment by an accredited third-party organisation

  • Alignment with RMF for OT - for suppliers with automation systems (HVAC, access control, power): coherent compliance with both CMMC and the Risk Management Framework

How we work, step by step

01

Scoping and level

We establish whether the entity processes FCI or CUI, which CMMC level applies, and where the boundary of in-scope systems runs.

02

Gap analysis (800-171)

We assess the 110 NIST SP 800-171 Rev. 2 requirements, document the state in the SSP and calculate the SPRS score per DoD methodology.

03

Remediation plan (POA&M)

We prioritise the gaps and build an action plan with a timeline that brings the organisation to the required level.

04

Control implementation

We support implementation of the missing controls - technical and organisational - and, for automation systems, coherent RMF compliance.

05

Certification readiness

We complete the evidence, run a readiness test and accompany you during the assessment by an accredited C3PAO.

The documents you take into a CMMC assessment

CMMC is assessed on documents and evidence. After the project you have a complete set that holds up in front of an assessor:

Scope and level
We establish whether you process FCI or CUI, which CMMC level applies to you and where the boundary of the CUI enclave runs.
System Security Plan (SSP)
The SSP describes the scope, architecture and implemented safeguards. Every assessment starts from this document.
NIST SP 800-171 assessment
The assessment shows the status of each of the 110 NIST SP 800-171 Rev. 2 requirements across 14 families.
SPRS score with justification
We calculate the score with the DoD methodology and document its justification, because an inflated score is a risk during verification.
POA&M
The plan sets deadlines for closing gaps within the limits CMMC allows.
Evidence package
We collect the evidence and check it in a readiness test before the C3PAO assessment.

Who we serve

We've worked with national energy grid operators, systemically important banks, industrial automation manufacturers, renewable energy operators, and US DoD contractors.

Technology partnerships

Not sure this service fits your situation? Describe your environment and deadline in a few lines and we will propose a scope. We reply within one business day.

Frequently asked questions

What is CMMC and who does it apply to?

The Cybersecurity Maturity Model Certification (CMMC 2.0) is a US Department of Defense programme that conditions participation in defense contracts on demonstrating compliance with information protection requirements. It applies across the entire Defense Industrial Base - including European subcontractors to US contractors and firms supplying equipment, services or works for US military installations. The programme has applied since 10 November 2025 and is phased in: since 10 November 2026 applicable solicitations require a Level 2 C3PAO certification, and from 10 November 2028 the requirements cover all applicable contracts, including options on existing ones.

What are the CMMC 2.0 levels?

Three. Level 1 applies to firms handling Federal Contract Information (FCI): it covers 15 requirements from FAR 52.204-21, needs an annual self-assessment and affirmation, and allows no POA&M. Level 2 applies to firms handling Controlled Unclassified Information (CUI): it covers the 110 requirements of NIST SP 800-171 Rev. 2 and is assessed either by the firm itself or, in most cases, by an accredited C3PAO every three years, with an annual affirmation. Level 3 is for the most sensitive programmes: it covers 24 selected requirements from NIST SP 800-172, is assessed by DCMA DIBCAC and is open only to firms that already hold a Level 2 C3PAO certification.

Does CMMC apply to companies outside the US?

Yes. The requirements flow down the supply chain through contract clauses. A European subcontractor to a US Department of Defense contractor that handles FCI or CUI may have to demonstrate compliance at the required level.

What is the SPRS score?

The Supplier Performance Risk System (SPRS) is a government system where suppliers enter their NIST SP 800-171 self-assessment score. The score is calculated per DoD methodology (weights of unmet requirements are subtracted from the maximum). We help calculate the score honestly and prepare the documentation that justifies it - an inflated score is a risk at verification.

What is scoping and why is it critical?

Scoping is defining the boundary of systems that process covered information. A properly separated CUI enclave lets you bring only the part of the environment that genuinely must comply into scope - instead of certifying the whole organisation. Incorrect scoping is the most common cause of inflated costs or gaps that void certification. That is why we start with it.

What are the SSP and POA&M?

The System Security Plan (SSP) is the document describing scope, architecture and implemented safeguards - the basis of any assessment. The Plan of Action and Milestones (POA&M) is a documented plan to close gaps with deadlines. CMMC permits limited use of a POA&M for selected requirements for a set period - we help build both documents so they withstand assessment.

How does CMMC connect to OT security?

In infrastructure projects the building automation systems (HVAC, access control, power) fall under the Risk Management Framework, while the information falls under CMMC. These are two different frameworks that must be met coherently. Our OT security experience lets us combine them in one approach, instead of running two disconnected projects - as in the delivery for the contractor on a US military construction project in Europe.

Where to start?

With scoping and determining the required level - this drives the cost and timeline of the whole engagement. Then the gap analysis against NIST SP 800-171 and the remediation plan. The initial consultation is free - we help assess whether and at what level CMMC genuinely applies before larger costs are incurred.

How do you price CMMC compliance support?

Most depends on scoping: a separate CUI enclave means fewer systems to assess than the whole organisation, and so fewer days. The price is the estimated days times the daily rate, with separate stages: scoping, gap analysis against NIST SP 800-171, SSP and POA&M, and preparation for the C3PAO assessment. We agree the scope on a free call.

We'll discuss scope, methodology, and timeline.

Free consultation, no strings attached.

Book a call