Skip to content

Oil & Gas

OT security for oil and gas

We help operators of pipelines, compressor stations, storage sites and refineries protect control and safety systems (DCS, SCADA, SIS) without stopping the process. We combine cybersecurity assessment with physical protection of sites spread over hundreds of kilometres.

NIS2CER DirectiveIEC 62443IEC 61511API 1164
Book a consultation

We reply within 1 business day

Challenges

Refinery control system security

DCS platforms, Safety Instrumented Systems (SIS), and Emergency Shutdown systems (ESD) require protection without disrupting continuous process operations. The 2017 Triton attack on a petrochemical facility in Saudi Arabia demonstrated that adversaries can target functional safety systems directly.

Pipeline infrastructure protection

SCADA systems monitoring transmission pipelines span hundreds of remote terminal units (RTUs) distributed across vast geographies. After the 2021 ransomware attack on Colonial Pipeline's IT systems, including billing, the operator shut down the entire pipeline as a precaution. It exposed the fragility of fuel supply chains.

Industrial protocols and legacy systems

Classic Modbus RTU and Modbus TCP, wired HART and Foundation Fieldbus H1 have no authentication or encryption. The secure variants, Modbus/TCP Security and HART-IP with TLS, are rarely available in older installations, and OPC UA security is often switched off (security mode None). That is why we assess segmentation, remote access and industrial traffic monitoring.

Zones and conduits in an industrial plantThe plant network split into zones: vendors, enterprise IT, IT/OT DMZ, SCADA operations, two control zones, a SIS zone and transient devices. Vendor remote access terminates on a jump host in the DMZ, historian data reaches the DMZ only through a data diode, and the conduit to the SIS zone is read-only. Z0Vendors outside SuC Vendor support,integrator Z1Enterprise zone (IT) outside SuC Office workstations ERP and reporting IT services (AD, e-mail) Z2IT/OT DMZ SL-T 3 Jump host (PAM) Historian replica Patch and AV relay Z3Operations zone (SCADA) SL-T 2 Engineering workstation Historian SCADA servers Z4aControl zone A SL-T 2 PLCs HMI panels Z4bControl zone B SL-T 2 PLCs HMI panels Z5SIS zone SL-T 3 Safety controller SIS engineering station Z6Transient devices SL-T 2 Service laptop,USB C1VPN gateway + MFA on request, to the jump host C2IT/DMZ firewall to DMZ services only C3DMZ/OT firewall sessions from the jump host only C4Data diode OT to DMZ only C5Industrial firewall protocol allowlist C6Industrial firewall protocol allowlist C7Firewall, read-only no writes to the SIS C8Scanning kiosk + NAC checked before connecting
Zones and conduits in an industrial plantThe plant network split into zones: vendors, enterprise IT, IT/OT DMZ, SCADA operations, two control zones, a SIS zone and transient devices. Vendor remote access terminates on a jump host in the DMZ, historian data reaches the DMZ only through a data diode, and the conduit to the SIS zone is read-only. Enterprise zone (IT) outside SuC IT/OT DMZ SL-T 3 Operations zone (SCADA) SL-T 2 Control zone A SL-T 2 SIS zone SL-T 3 C2IT/DMZ firewall C3DMZ/OT firewall C4Data diode C5Industrial firewall C7Read-only
Fig. 1. Zones and conduits in an industrial plant. Layout based on ANSI/ISA-62443-1-1 (figures 16-18) and IEC 62443-3-2. SL-T values are illustrative; in a project they come from the risk assessment.

Not sure where to start in your organisation? Tell us which systems and regulations apply to you and we will suggest a first step. We reply within one business day.

Let's talk

Frequently asked questions

Do you assess physical security of sites?

Yes, as part of OT security. For a transmission system operator we checked a compressor station, a valve station and a control centre for physical access to control cabinets, network ports and HMI stations. We found more than 40 vulnerabilities and marked 12 attack vectors to fix first.

How does IEC 61511 relate to cybersecurity?

IEC 61511-1:2016 (clause 8.2.4) requires a security risk assessment of the SIS and connected control systems. We help prepare it using IEC 62443 so that the results feed into your functional safety documentation.

We'll discuss scope, methodology, and timeline.

Free consultation, no strings attached.

Book a call