Oil & Gas
OT security for oil and gas
We help operators of pipelines, compressor stations, storage sites and refineries protect control and safety systems (DCS, SCADA, SIS) without stopping the process. We combine cybersecurity assessment with physical protection of sites spread over hundreds of kilometres.
We reply within 1 business day
Challenges
Refinery control system security
DCS platforms, Safety Instrumented Systems (SIS), and Emergency Shutdown systems (ESD) require protection without disrupting continuous process operations. The 2017 Triton attack on a petrochemical facility in Saudi Arabia demonstrated that adversaries can target functional safety systems directly.
Pipeline infrastructure protection
SCADA systems monitoring transmission pipelines span hundreds of remote terminal units (RTUs) distributed across vast geographies. After the 2021 ransomware attack on Colonial Pipeline's IT systems, including billing, the operator shut down the entire pipeline as a precaution. It exposed the fragility of fuel supply chains.
Industrial protocols and legacy systems
Classic Modbus RTU and Modbus TCP, wired HART and Foundation Fieldbus H1 have no authentication or encryption. The secure variants, Modbus/TCP Security and HART-IP with TLS, are rarely available in older installations, and OPC UA security is often switched off (security mode None). That is why we assess segmentation, remote access and industrial traffic monitoring.
Not sure where to start in your organisation? Tell us which systems and regulations apply to you and we will suggest a first step. We reply within one business day.
Let's talkServices
OT Security Assessment
We show which paths lead to your controllers and what to fix first.
IEC 62443 Audit
We establish the SL-A your zones and conduits achieve and what separates it from the SL-T.
NIS2 Compliance Audit
We establish whether NIS2 applies to you and which security measures are still missing.
Penetration Testing
We show what an attacker could achieve through the flaws, and retest after your fixes.
Incident Readiness
You get a response plan and playbooks tested with your team in a tabletop exercise.
Frequently asked questions
Do you assess physical security of sites?
Yes, as part of OT security. For a transmission system operator we checked a compressor station, a valve station and a control centre for physical access to control cabinets, network ports and HMI stations. We found more than 40 vulnerabilities and marked 12 attack vectors to fix first.
How does IEC 61511 relate to cybersecurity?
IEC 61511-1:2016 (clause 8.2.4) requires a security risk assessment of the SIS and connected control systems. We help prepare it using IEC 62443 so that the results feed into your functional safety documentation.
We'll discuss scope, methodology, and timeline.