Skip to content

Energy

OT security for the energy sector

We help grid operators, generators and renewable asset owners protect SCADA, AMI and operational networks without interrupting operations. We have tested the energy market data exchange platform and prepared AMI security requirements for tenders and a draft national certification scheme for meters.

NIS2Network Code on CybersecurityIEC 62443ISO/IEC 27019
Book a consultation

We reply within 1 business day

Challenges

Operational networks and SCADA

We check whether the operational network can be reached from IT, via VPN or by plugging in on site. We schedule tests in agreed time windows, as in the audit of an energy operator's technological network.

AMI and energy market systems

We assess AMI security from the meter to the head-end system. For a distribution system operator we examined the devices by reverse engineering, and for a buyer in the distribution sector we prepared security requirements for a tender.

Wind and solar farms

Distributed controllers in renewable farms connect to a monitoring centre and to the vendor's service. We assess these connections and remote access, as we did at a European operator's wind farm.

Zones and conduits in a renewable plant with its grid connectionThe generator's network split into zones: vendors and service, generator IT, DMZ, fleet control centre, grid connection substation with RTUs, and the plant field, with the grid operator outside the system. Service staff come in only through a VPN with MFA to a jump host, every site has its own VPN, and the substation talks to the grid operator over a serial link. Z0Vendors and service outside SuC OEM service Integrator Z1Grid operator (SCADA) outside SuC Operator dispatch Z2Generator IT SL-T 1 Office and ERP IT services Z3DMZ SL-T 3 Jump host Data replica Z4Fleet control centre SL-T 2 Fleet SCADA Historian Z5Grid connection substation SL-T 3 RTU Local HMI Protection relays Z6Plant field SL-T 2 Inverters or turbines Controllers C1VPN gateway + MFA on request, to the jump host C2IT/DMZ firewall to DMZ services only C3DMZ/OT firewall sessions from the jump host only C4Per-site VPN one account reaches one site only C5Serial link to the grid operator's SCADA C6Industrial firewall protocol allowlist C7APN with device isolation backup link
Zones and conduits in a renewable plant with its grid connectionThe generator's network split into zones: vendors and service, generator IT, DMZ, fleet control centre, grid connection substation with RTUs, and the plant field, with the grid operator outside the system. Service staff come in only through a VPN with MFA to a jump host, every site has its own VPN, and the substation talks to the grid operator over a serial link. Vendors and service outside SuC DMZ SL-T 3 Fleet control centre SL-T 2 Grid connection SL-T 3 C1VPN + MFA C3DMZ/OT firewall C4Per-site VPN C7Isolated APN
Fig. 1. Zones and conduits in a renewable plant with its grid connection. Layout based on ANSI/ISA-62443-1-1 (figures 20 and 22) and the grid connection described in the CERT Polska 2025 report. SL-T values are illustrative; in a project they come from the risk assessment.

Not sure where to start in your organisation? Tell us which systems and regulations apply to you and we will suggest a first step. We reply within one business day.

Let's talk

Frequently asked questions

Can an OT audit disrupt grid operations?

We plan tests in the operational network together with the operator: agreed time windows, a communication path if a critical vulnerability is found and systems excluded from active testing. This is how we ran the audit of an energy operator's technological network.

What is the Network Code on Cybersecurity and who does it apply to?

It is Commission Delegated Regulation (EU) 2024/1366 on cybersecurity aspects of cross-border electricity flows, in force since 13 June 2024. It applies to electricity sector entities identified as high-impact or critical-impact. Requirements are phased in alongside NIS2.

We'll discuss scope, methodology, and timeline.

Free consultation, no strings attached.

Book a call