Energy
|CS.118
SCADA System Compliance with IEC 62443-4-1 and 4-2
A SCADA manufacturer aligned its development process with IEC 62443-4-1 and its product with IEC 62443-4-2 requirements for SL-C 2. We supported the gap analysis and the external assessment.
Client
SCADA system manufacturer
Challenge
The SCADA manufacturer had to demonstrate compliance with two parts of the standard at once: IEC 62443-4-1 (secure development lifecycle) and IEC 62443-4-2 (technical requirements for components). That required changes both to the development processes (SDL) and to the product itself.
Approach
Gap analysis and product review
Assessment of the development processes against IEC 62443-4-1 and of the product against IEC 62443-4-2: authentication, authorisation, integrity and confidentiality. Choice of SL-C 2 as the capability level the product components must reach.
4-phase compliance plan
Gap analysis, remediation, internal audit and support during the external assessment - with completion criteria for each phase.
Implementing the changes
Supporting the teams with SDL process changes (security requirements, threat modelling, testing, vulnerability handling) and with the product changes required for SL-C 2.
Internal audit and external assessment
An internal audit with a compliance evidence package, followed by support for the manufacturer during the assessment by an independent body.
Results
The manufacturer aligned its development process with IEC 62443-4-1 and its product with IEC 62443-4-2 at SL-C 2.
The development process is aligned with IEC 62443-4-1.
The product meets the IEC 62443-4-2 requirements for SL-C 2.
The compliance evidence package passed an internal audit.
We supported the manufacturer during the assessment by an independent body.
Planning a similar project?
30 minutes with a consultant who runs projects like yours. We agree the scope and tell you what the price depends on.
Related case studies
CS.104
Advanced Red Team Testing in the Energy Sector
The attack simulation exposed critical IT and OT vulnerabilities, which the company removed, as retests confirmed.
CS.105
Identity and Access Management System Testing
Tests of AD, ADFS and PKI found configuration gaps an attacker could exploit and produced a prioritised remediation plan.
CS.107
AMI system security for a distribution system operator
Reverse engineering found critical vulnerabilities in AMI devices, and the operator has security procedures for the system.
We'll discuss scope, methodology, and timeline.